Z Corporation ZScanner 700 option in Rapidform XOR

Options in Detail

1. Configure

image47_1208

l Session

New – Starts a new session.

Open – Opens an existing session file (.CSF)

Save – Saves the current session (.CSF)

l Positioning Features

Open – Opens existing positioning targets file (.TXT).

Copy – Copies positioning targets to a new scan.

Save – Saves positioning targets in file (.TXT)

l Scan List – It shows existing scans of current session and highlights the current scan.

Add – Adds a scan in the current session.

Rename Scan – Changes name of current scan to the name in the Current Scan box.

Remove Scan – Removes current scan.

l Sensor

Sensor Configuration – Shows the Sensor Configuration dialog box of Handyscan 3D.

Sensor Calibration – Shows the Sensor Calibration dialog box of Handyscan 3D.

l Scan Backup Path – You can set the backup folder of scan data.

2 Scan

image47_1210

l Scan

Start – If you click this button, it starts scanning.

Stop – If you click this button, it stops current scanning.

Reset – If you click this button, it clears the scan data of the current scan.

Surface – This mode gathers both surface data and positioning features during scanning.

Positioning Features – This mode gathers only positioning features during scanning.

Show Current Scan Only – If checked, it shows only the scan data of the selected scan.

Hide Positioning Feature When Surface Scanning – If checked, the positioning features will be hidden during scanning.

Hide Positioning Feature When Surface Scanning – If checked, the positioning features will be hidden during scanning.

Show ZScan Entity Only – If checked, It shows only shells and ref.points entities related to scan data.

Open ZScan Window – Opens VxScan window. It allows the user to access all the functions that VxScan provides.

l Surface Parameter – You can set the scanning volume size or resolution. After changing the settings, you have to click Apply or Cancel button.

Volume Size – Adjust surface reconstruction settings according to your needs.

This sets the scanning volume. Changing the volume size has a direct impact on the voxel size of each resolution level.

Resolution – You can select High, Med or Low resolution.

Apply – Confirms the setting.

Cancel – Restores previous settings.

Center Volume – Centers the volume on the object being scanned.

Refine – Performs an operation on the surface that will decrease the impact of possible positioning errors that may occur during the scan.

l Facet Parameter – You can set the scanning volume size or resolution. After changing the settings, you have to click Apply or Cancel button.

Spike Filter – It determines the level of spike filtering.

Fill Positioning Features – If checked, the application fills holes created by the positioning features on the object.

Apply – Confirms the settings.

Cancel – Restore previous settings.