Specify general system options such as the display of error and warning icons in the Simulation study tree, options for mesh and plot appearance, etc. System options apply to all studies in all documents.
To set the General options:
- Click .The System Options – General dialog box appears.
- Select from the options described below, then click OK.
What’s Wrong Messages
Load/Fixture symbol quality
Specifies the quality of the load and fixture symbols.
Mesh colors
Sets colors for plotting the mesh.
Boundary color | Sets the color for plotting element edges. | ||||
Shell bottom face color | Sets the color for plotting the bottom faces of shell elements.
|
To change a color, select Boundary color or Shell bottom face color, click Edit, then choose a color, and click OK.
Result plots
Dynamic plot update | When checked, plots are dynamically updated as the parameters that control the plots appearance are modified. Turn the flag off to improve performance of viewing results for large models. |
List result quantities in higher precision | When checked, results are listed with up to 16-digit precision. |
Show yield strength marker for vonMises plots | When checked, the location of the material yield strength on the plot legend for studies with parts is marked with a red arrow. The yield strength value is displayed at the bottom of the plot legend. |
Display local coordinate system reference triad | When checked, the local coordinate system reference triad is displayed at the lower right corner of the graphics area. The triad is displayed only for plots where you define a reference plane, axis, or coordinate system. |
Color chart background color | Sets the background color for the plot legend. |
Hide excluded bodies and show study material appearances (requires more time to load a study) | When selected:
When this option is selected, for large assemblies with many material assignments or many bodies excluded from analysis, activating a simulation study can take a significant amount of time (because the system must apply the internal simulation-specific display state on top of the model display state). However, interactive performance while editing the simulation study is not affected. To avoid these performance issues, turn this option off.
|
Font
Enables you to select fonts for the Plot Title, Plot Subtitle, and Color Chart.
Simulation Advisor
Run Simulation Advisor from CommandManager | When checked, Simulation Advisor starts when you click Study, Fixtures, External Loads, Connections, or Results on the Simulation CommandManager. When cleared, you can start the Advisors by clicking Study, Fixtures, External Loads, Connections, or Results on the Simulation CommandManager and selecting the corresponding Advisor from the menu.
If you change this option, you must restart SolidWorks for the change to take effect.
|